Fiber-optic Singlet Oxygen [1 O2 ( 1 Dg)] Generator Device Serving as a Point Selective Sterilizer

David Aebisher, Matibur Zamadar, Adaikapillaic Mahendran, Goutam Ghosh, Cathy McEntee, Alexander Greer

Research output: Contribution to journalArticle

Abstract

Traditionally, Type II heterogeneous photo-oxidations produce singlet oxygen via external irradiation of a sensitizer and external supply of ground-state oxygen. A potential improvement is reported here. A hollow-core fiber-optic device was developed with an ‘‘internal’’ supply of light and flowing oxygen, and a porous photosensitizer-end capped configuration. Singlet oxygen was delivered through the fiber tip. The singlet oxygen steady-state concentration in the immediate vicinity of the probe tip was ca 20 fM by N-benzoyl-DL-methionine trapping. The device is portable and the singlet oxygen-generating tip is maneuverable, which opened the door to simple disinfectant studies. Complete Escherichia coli inactivation was observed in 2 h when the singlet oxygen sensitizing probe tip was immersed in 0.1 mL aqueous samples of 0.1–4.4 · 107 cells. Photobleaching of the probe tip occurred after ca 12 h of use, requiring baking and sensitizer reloading steps for reuse.

Original languageUndefined/Unknown
JournalFaculty Publications
StatePublished - Jan 1 2010

Cite this